Hand Detection

Detection of the presence of a person's body in the dangerous area

Detection of the body through access control



VISION V 20mm Low Range
Hand Detection
ModelV 152 LV 302 LV 452 LV 602 LV 752 LV 902 LV 1052 LV 1202 LV 1352 LV 1502 LV 1652 LV 1802 L
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)1,02E-081,17E-081,33E-081,48E-081,63E-081,79E-081,94E-082,10E-082,25E-082,40E-082,56E-082,71E-08
DCavg (ISO 13849-1)97,77%98,07%98,25%98,38%98,47%98,53%98,58%98,63%98,66%98,69%98,71%98,73%
MTTFd (ISO 13849-1) years10092,1481,9673,8067,1261,5556,8352,79
CCF (ISO 13849-1)80%
Protected height mm160310460610760910106012101360151016601810
Number of beams153045607590105120135150165180
Response time ms78,510,512,514,516,5182022242628
Total barrier height mm2614115617118611011116113111461161117611911
Resolution mm20
Maximun scanning range6
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignallingLeds for barrier's status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing modesBack or side slot, top and lower end
Cross section dimensions mm35 x 45

[Top Page]

VISION V 20mm High Range
Hand Detection
ModelV 152 HV 302 HV 452 HV 602 HV 752 HV 902 HV 1052 HV 1202 HV 1352 HV 1502 HV 1652 HV 1802 H
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)1,02E-081,17E-081,33E-081,48E-081,63E-081,79E-081,94E-082,10E-082,25E-082,40E-082,56E-082,71E-08
DCavg (ISO 13849-1)97,77%98,07%98,25%98,38%98,47%98,53%98,58%98,63%98,66%98,69%98,71%98,73%
MTTFd (ISO 13849-1) years10092,1481,9673,8067,1261,5556,8352,79
CCF (ISO 13849-1)80%
Protected height mm160310460610760910106012101360151016601810
Number of beams153045607590105120135150165180
Response time ms78,510,512,514,516,5182022242628
Total barrier's height mm2614115617118611011116113111461161117611911
Resolution mm20
Maximum scanning range16
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 30mm Low Range
Hand Detection
ModelV 153 LV 303 LV 453 LV 603 LV 753 LV 903 LV 1053 LV 1203 LV 1353 LV 1503 LV 1653 LV 1803 L
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)9,58E-091,05E-081,14E-081,24E-081,33E-081,42E-081,51E-081,61E-081,70E-081,79E-081,88E-081,98E-08
DCavg (ISO 13849-1)97,58%97,84%98,02%98,16%98,26%98,34%98,40%98,45%98,50%98,53%98,57%98,59%
MTTFd (ISO 13849-1) years10099,3491,9385,5579,99
CCF (ISO 13849-1)80%
Protected height mm160310460610760910106012101360151016601810
Number of beams81624324048566472808896
Response time ms67891011121314151617
Total barrier's height mm2614115617118611011116113111461161117611911
Resolution mm30
Maximum scanning range6
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 30mm High Range
Hand Detection
ModelV 153 HV 303 HV 453 HV 603 HV 753 HV 903 HV 1053 HV 1203 HV 1353 HV 1503 HV 1653 HV 1803 H
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)9,58E-091,05E-081,14E-081,24E-081,33E-081,42E-081,51E-081,61E-081,70E-081,79E-081,88E-081,98E-08
DCavg (ISO 13849-1)97,58%97,84%98,02%98,16%98,26%98,34%98,40%98,45%98,50%98,53%98,57%98,59%
MTTFd (ISO 13849-1) years10099,3491,9385,5579,99
CCF (ISO 13849-1)80%
Protected height mm160310460610760910106012101360151016601810
Number of beams81624324048566472808896
Response time ms67891011121314151617
Total barrier's height mm2614115617118611011116113111461161117611911
Resolution mm30
Maximum scanning range16
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 40mm Low Range
Hand Detection
ModelV 304 LV 454 LV 604 LV 754 LV 904 LV 1054 LV 1204 LV 1354 LV 1504 LV 1654 LV 1804 L
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)1,01E-081,09E-081,17E-081,24E-081,32E-081,39E-081,47E-081,54E-081,62E-081,69E-081,77E-08
DCavg (ISO 13849-1)97,76%97,93%98,06%98,16%98,24%98,31%98,37%98,42%98,46%98,49%98,52%
MTTFd (ISO 13849-1) years10093,89
CCF (ISO 13849-1)80%
Protected height mm310460610760910106012101360151016601810
Number of beams1015202530354045505560
Response time ms677,588,59,51010,5111212,5
Total barrier's height mm4115617118611011116113111461161117611911
Resolution mm40
Maximum scanning range6
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 40mm High Range
Hand Detection
ModelV 304 HV 454 HV 604 HV 754 HV 904 HV 1054 HV 1204 HV 1354 HV 1504 HV 1654 HV 1804 H
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)1,01E-081,09E-081,17E-081,24E-081,32E-081,39E-081,47E-081,54E-081,62E-081,69E-081,77E-08
DCavg (ISO 13849-1)97,76%97,93%98,06%98,16%98,24%98,31%98,37%98,42%98,46%98,49%98,52%
MTTFd (ISO 13849-1) years10093,89
CCF (ISO 13849-1)80%
Protected height mm310460610760910106012101360151016601810
Number of beams1015202530354045505560
Response time ms677,588,59,51010,5111212,5
Total barrier's height mm4115617118611011116113111461161117611911
Resolution mm40
Maximum scanning range16
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 50mm Low Range
Detection of the presence of a person's body in the dangerous area
ModelV 305 LV 455 LV 605 LV 755 LV 905 LV 1055 LV 1205 LV 1355 LV 1505 LV 1655 LV 1805 L
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)1,00E-081,07E-081,14E-081,21E-081,28E-081,35E-081,42E-081,49E-081,56E-081,63E-081,70E-08
DCavg (ISO 13849-1)97,72%97,89%98,02%98,12%98,21%98,28%98,33%98,38%98,43%98,46%98,49%
MTTFd (ISO 13849-1) years10099,66
CCF (ISO 13849-1)80%
Protected height mm310460610760910106012101360151016601810
Number of beams812162024283236404448
Response time ms66,577,588,599,51010,511
Total barrier's height mm4115617118611011116113111461161117611911
Resolution mm50
Maximum scanning range6
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignaligLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 50mm High Range
Detection of the presence of a person's body in the dangerous area
ModelV 305 HV 455 HV 605 HV 755 HV 905 HV 1055 HV 1205 HV 1355 HV 1505 HV 1655 HV 1805 H
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)1,00E-081,07E-081,14E-081,21E-081,28E-081,35E-081,42E-081,49E-081,56E-081,63E-081,70E-08
DCavg (ISO 13849-1)97,72%97,89%98,02%98,12%98,21%98,28%98,33%98,38%98,43%98,46%98,49%
MTTFd (ISO 13849-1) years10099,66
CCF (ISO 13849-1)80%
Protected height mm310460610760910106012101360151016601810
Number of beams812162024283236404448
Response time ms66,577,588,599,51010,511
Total barrier's height mm4115617118611011116113111461161117611911
Resolution mm50
Maximum scanning range16
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 90mm Low Range
Detection of the body through access control
ModelV 309 LV459 LV 609 LV 759 LV 909 LV 1059 LV 1209 LV 1359 LV 1509 LV 1659 LV 1809 L
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)9,78E-091,04E-081,09E-081,15E-081,21E-081,27E-081,32E-081,38E-081,44E-081,50E-081,55E-08
DCavg (ISO 13849-1)97,65%97,81%97,93%98,04%98,12%98,19%98,25%98,30%98,35%98,39%98,42%
MTTFd (ISO 13849-1) years100
CCF (ISO 13849-1)80%
Protected height mm310460610760910106012101360151016601810
Number of beams5791113151719212325
Response time ms5,566,577,58
Total barrier's height mm4115617118611011116113111461161117611911
Resolution mm90
Maximum scanning range6
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operatig temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 90mm High Range
Detection of the body through access control
ModelV 309 HV 459 HV 609 HV 759 HV 909 HV 1059 HV 1259 HV 1359 HV 1509 HV 1659 HV 1809 H
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)9,78E-091,04E-081,09E-081,15E-081,21E-081,27E-081,32E-081,38E-081,44E-081,50E-081,55E-08
DCavg (ISO 13849-1)97,65%97,81%97,93%98,04%98,12%98,19%98,25%98,30%98,35%98,39%98,42%
MTTFd (ISO 13849-1) years100
CCF (ISO 13849-1)80%
Protected height mm310460610760910106012101360151016601810
Number of beams5791113151719212325
Response time ms5,566,577,58
Total barrier's height mm4115617118611011116113111461161117611911
Resolution mm90
Maximum scanning range16
Safety outputs2 PNP - 500 mA @ 24 Vdc
SignalingLeds for barrier´s status and diagnostic
Power supply24 ± 20%
ConnectionsConnectors M12 5 - pole
Max lenght of the connection100
Operating temp. °C0 ÷ 55
Degree of protectionIP 65
Fixing's modesBack or side slot, top and lower end
Cross section dimensions35 x 45

[Top Page]

VISION V 2,3,4 beams Low Range
Detection of the body through access control
ModelV 2B LV 3B LV 4B L
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)8,97E-099,15E-099,32E-09
DCavg (ISO 13849-1)97,30%97,40%97,49%
MTTFd (ISO 13849-1) years100
CCF (ISO 13849-1)80%
Protected height mm500800900
Number of beams234
Response time ms6
Total barrier's height mm71110111111
Safety level6
Maximum scanning range m2 PNP - 500 mA @ 24 Vdc
Safety outputsLeds for barrier's status and and diagnostic
Signaling24 ± 20%
Power supplyConnectors M12 5 - pole
Connections100
Max lenght of the connection0 ÷ 55
Operating temp. °CIP 65
Degree of protectionBack or side slot, top and lower end
Fixing's modes35 x 45
Cross section dimensions

[Top Page]

VISION V 2,3,4 beams High Range
Detection of the body through access control
ModelV 2B HV 3B HV 4B H
Safety levelType 2 - SIL 2 - SILCL 2 - PL d - Cat.2
PFHd (IEC 61508)8,97E-099,15E-099,32E-09
DCavg (ISO 13849-1)97,30%97,40%97,49%
MTTFd (ISO 13849-1) years100
CCF (ISO 13849-1)80%
Protected height mm500800900
Number of beams234
Response time ms6
Total barrier's height mm71110111111
Safety level16
Maximum scanning range m2 PNP - 500 mA @ 24 Vdc
Safety outputsLeds for barrier's status and and diagnostic
Signaling24 ± 20%
Power supplyConnectors M12 5 - pole
Connections100
Max lenght of the connection0 ÷ 55
Operating temp. °CIP 65
Degree of protectionBack or side slot, top and lower end
Fixing's modes35 x 45
Cross section dimensions

[Top Page]